Salahuddin Ahmad to Radiometry
This is a "connection" page, showing publications Salahuddin Ahmad has written about Radiometry.
Connection Strength
2.960
-
Interplay effect of angular dependence and calibration field size of MapCHECK 2 on RapidArc quality assurance. J Appl Clin Med Phys. 2014 May 08; 15(3):4638.
Score: 0.445
-
Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology. Med Phys. 2010 Jul; 37(7):3560-8.
Score: 0.341
-
Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging. J Appl Clin Med Phys. 2010 May 20; 11(3):3192.
Score: 0.338
-
A comparative study of seed localization and dose calculation on pre- and post-implantation ultrasound and CT images for low-dose-rate prostate brachytherapy. Phys Med Biol. 2009 Sep 21; 54(18):5595-611.
Score: 0.321
-
Impact of margin on tumour and normal tissue dosimetry in prostate cancer patients treated with IMRT using an endorectal balloon for prostate immobilization. Australas Phys Eng Sci Med. 2005 Dec; 28(4):209-15.
Score: 0.248
-
Quantitative evaluation of dosimetric uncertainties associated with small electron fields. J Med Imaging Radiat Sci. 2022 06; 53(2):273-282.
Score: 0.192
-
Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system. J Appl Clin Med Phys. 2022 Jan; 23(1):e13478.
Score: 0.188
-
Dosimetric effects of positioning shifts using 6D-frameless stereotactic Brainlab system in hypofractionated intracranial radiotherapy. J Appl Clin Med Phys. 2016 01 08; 17(1):102-111.
Score: 0.125
-
Dosimetric and radiobiologic comparison of 3D conformal, IMRT, VMAT and proton therapy for the treatment of early-stage glottic cancer. J Med Imaging Radiat Oncol. 2015 Apr; 59(2):221-8.
Score: 0.113
-
Dependency of planned dose perturbation (PDP) on the spatial resolution of MapCHECK 2 detectors. J Appl Clin Med Phys. 2014 Jan 06; 15(1):4457.
Score: 0.109
-
A comprehensive comparison study of three different planar IMRT QA techniques using MapCHECK 2. J Appl Clin Med Phys. 2013 Nov 04; 14(6):4398.
Score: 0.107
-
Evaluation of different techniques for CT radiation profile width measurement. J Appl Clin Med Phys. 2013 Jul 08; 14(4):4122.
Score: 0.105
-
Comparison of tumor and normal tissue dose for accelerated partial breast irradiation using an electronic brachytherapy eBx source and an Iridium-192 source. J Appl Clin Med Phys. 2010 Sep 14; 11(4):3301.
Score: 0.086
-
Single pulse protoacoustic range verification using a clinical synchrocyclotron. Phys Med Biol. 2023 02 08; 68(4).
Score: 0.051
-
Characterization of penumbra sharpening and scattering by adaptive aperture for a compact pencil beam scanning proton therapy system. Med Phys. 2021 Apr; 48(4):1508-1519.
Score: 0.045
-
Performance evaluation of adaptive aperture's static and dynamic collimation in a compact pencil beam scanning proton therapy system: A dosimetric comparison study for multiple disease sites. Med Dosim. 2021 Summer; 46(2):179-187.
Score: 0.044
-
A complete workflow for utilizing Monte Carlo toolkits in clinical cases for a double-scattering proton therapy system. J Appl Clin Med Phys. 2019 Jan; 20(1):23-30.
Score: 0.038
-
Comparability of three output prediction models for a compact passively double-scattered proton therapy system. J Appl Clin Med Phys. 2017 May; 18(3):108-117.
Score: 0.034
-
Normal Brain Sparing With Increasing Number of Beams and Isocenters in Volumetric-Modulated Arc Beam Radiosurgery of Multiple Brain Metastases. Technol Cancer Res Treat. 2016 12; 15(6):766-771.
Score: 0.031